Fire suppression control units and accessories
Mircom’s FX-3500 Series systems are powerful Intelligent Fire / Agent Release Control Units that are UL/ULC listed for fire alarm services, including releasing service.
The FX-3500 Series provides up to three intelligent Data Communication Links (DCLs) / Signaling Line Circuits (SLCs) that support a new AP protocol, which is faster and has capacity for
up to 954 intelligent devices.
In addition, the FX-3500 Series has backward compatibility support for CLIP devices. The FX-3500 Series systems are recommended for both new and retrofit fire detection and/or special-hazard/critical-infrastructure suppression/special agent applications.
Capable of releasing up to six discrete physical hazard zones, the
FX-3500 offers exceptional value for complex installations.
Elegant configuration options by onsite laptop, or when required by the Engineer of Record, by remote PC via modem, the FX-3500 can be operational with minimal set up time.
Programming versatility makes the FX-3500 Series the ideal choice for dependable fire detection, signaling and protection in industrial, commercial and institutional buildings.
General Benefits
Intelligent addressable fire alarm
with releasing control.
-
New fast AP protocol, extending number of devices on the loops, up to 954 (318 X3)
-
Panel supports both AP and CLIP protocol
-
Uses USB key for enhanced security
-
Utilizing cross-zoning or counting detection
-
Flush or Surface mountable with no additional hardware required
-
Utilizes the universal Mircom enclosure.
Mechanical Features
-
The FX-3500 supports both flush and surface mount applications;
-
Dimensions 26” x 14.5” x 4.2”66 cm x 36 cm x 11 cm
-
Modular display placement options;
-
Fits up to 2, 18 Ampere Hour batteries.
-
Durable CAT-30 lock and key.
-
Removable enclosure door.
-
Easy access to all modules for serviceability.
Additional Features
-
Compatible with INX-10A Addressable Intelligent NAC Expander Panel.
-
Supports Acclimate smoke detection sensors.
Hardware Features
-
One onboard SLC/DCL communication circuit that supports up 318 addressable devices/points;
-
Expandable to three SLC/DCL communication circuits that supports up to 954 addressable devices/points;
-
Reliable and industry proven dedicated releasing power supply;
-
Six dedicated hazard zone LED indicators;
-
Convenient USB Programming port;
-
Built-in UDACT/DACT for remote monitoring;
-
Enhanced tactile response for operator interface;
-
4 x 20 character Liquid Crystal Display (LCD);
-
Easy to read numerical keypad;
-
10 Ampere (Amp.) Power Supply to satisfy typical releasing load requirements;
-
Four Class A/B Notification Appliance Circuits (NAC) rated at 1.5Amp. each;
-
SLC is capable of NFPA 72 Style 4, Style 6, or Style 7 wiring & ULC’s DCL-A & DCL-B;
-
Resettable auxiliary power supply;
-
Four easy to read status queues with selector switches and LEDs for Alarm, Supervisory, Trouble and Building Safety (Formerly Monitor) Input visual indications;
-
Supports up to seven remote annunciators;
-
Accessible multifunction RS-232 port for:
-
Audio Interface
-
Serial Communication interface
-
RS-485 Interface for remote LCD/LED Annunciators and other devices;
-
Optional City Tie/Polarity Reversal module for central station monitoring.
-
Cross-zoned or Counting Zone Smoke Detection programming to enable release by either counting active zone detection circuits or active cross-zoned detection circuits (includes options for single, double, triple and 2 different inputs counting zones)
Software and Operational Features
-
Audible alarm response within three seconds of activation in Advanced Protocol mode (when using AP devices only);
-
AP is a completely digital protocol;
-
AP is an Interrupt base protocol;
-
Individual LED Control;
-
Releasing capability for up to 6 Zones
-
Supports Pre-Action/Agent Release and Deluge Applications;
-
Supports up to 3 SLC loops and 954 points
-
Supports CLIP and AP System Sensor protocols;
-
Built-in strobe synchronization support for Mircom, Potter/Amseco, System Sensor, Gentex and Wheelock protocols;
-
Grouped inputs and outputs;
-
NACs can be configured as Silenceable or Non-Silenceable for both signals and strobes;
-
Group bypass with built-in false alarm prevention technology;
-
Zone Counting;
-
Built-in Drift Compensation for AP protocol;
-
Positive Alarm Sequence;
-
Configurable Signal Silence Inhibit, Auto Signal Silence, Two Stage Operation and One-Man Walk Test;
-
Relay contacts for Common Alarm, Auxiliary/Alarm (Disconnectable), Common Supervisory and Common Trouble;
-
Two event history logs comprised of a 400 event alarm log for alarm related events and a 400 event general log for all other events;