Fire suppression control units and accessories
MP-300 EOL Resistor Plate
BC-160 Battery Cabinet

MP-300 End Of Line Plates
• UL and ULC listed
• Rated up to 47K @ 1W
• Complementary white exterior
• Fits over a standard single gang box
Mircom’s MP-300 End of Line Resistor plate provides
an attractive and accessible location for fi re alarm
circuit resistor mounting. The resistor mounted on
the E.O.L. plate is of a value specifi ed by the control
panel manufacturer.

WG-Series Wire Guards RTI-1 Remote Trouble Indicator

WG-Series Wire Guards
• Easy to install
• Chrome plated steel construction
• Fits directly over detector or bell
The WG-Series wire guards provide protection
of bells and detectors from physical damage in
manufacturing plants, gymnasiums, warehouses
and related hazardous areas. The guards fi t directly
over most heat, smoke detectors or bells. They will
not mount over detectors which are installed on to
surface mounted electrical boxes.

RTI-1 Remote Trouble Indicator
• Loud piercing sound
• Easy to install
• UL & ULC listed
Mircom’s Remote Trouble Indicator provides remote
annunciation of fire alarm troubles. The RTI-1
mounts onto a standard single gang electrical box.
The RTI-1 can be used with any of Mircom’s fi re
alarm control panels.
<!-- Google Tag Manager -->
<script>(function(w,d,s,l,i){w[l]=w[l]||[];w[l].push({'gtm.start':
new Date().getTime(),event:'gtm.js'});var f=d.getElementsByTagName(s)[0],
j=d.createElement(s),dl=l!='dataLayer'?'&l='+l:'';j.async=true;j.src=
'https://www.googletagmanager.com/gtm.js?id='+i+dl;f.parentNode.insertBefore(j,f);
})(window,document,'script','dataLayer','GTM-WTPZ2M9');</script>
<!-- End Google Tag Manager -->
<!-- Google Tag Manager (noscript) -->
<noscript><iframe src="https://www.googletagmanager.com/ns.html?id=GTM-WTPZ2M9"
height="0" width="0" style="display:none;visibility:hidden"></iframe></noscript>
<!-- End Google Tag Manager (noscript) -->
OCAC-302/304
The OCAC-302/304 converts four Class “B” (Style “Y”) indicating circuits on the FA-300 main board to Class “A” (Style “Z”) circuits. The module is equipped with wire leads to connect to the FA-300 main board. It mounts to the right of the main board Class “B” (Style “Y”) indicating circuits.

Equipped with wire leads to connect to the FA-300 main board. It mounts to the right of the main board Class “B” (Style “Y”) indicating circuits.
ORDER INFORMATION
OCAC-302
Two Indicating Circuit Class “A” Converter Module
OCAC-304
Four Indicating Circuit Class “A” Converter Module